Having major problems with headlights and spots.

This site contains affiliate links for which LandyZone may be compensated if you make a purchase.

jollyfarmer

New Member
Posts
36
Location
North East Derbyshire
hi all,
i'm new to this whole post the problem on the internet so appologies if i make it difficult to understand.
i recently bought a light bar with 4 ring spots and 2 wipac safari spots which are on the A bar on the front for my 1986 defender. i wired them all up correctly (to the high beam)with all the relays and what not. it looked mint.
went back the next day and on the first flash they worked fine. i put the lights on sidelights worked, main beam didn't but full beam and all the spots did. so i tried again with the light switch same again but spots on the roof bar didn't work. tried again lost the wipacs and again....only have side lights and left full beam???:(
i replaced: headlights with halogen conversion
light switch
indicater stalk
checked all fuses they appear fine. i'm really stuck for ideas?? any help i would be really greatful :)
 
too much wattage i would guess for the light stalk too handle..

i have 4 wipacs on my abar with 2 relays and 55w bulbs in em theese are wired to main beam

i have 4 lights on roof bar with 55w bulbs in em wired via 2 relays and a seperate switch on the dash..
i think you have too much on one switched source..how many relays u runnin? should be a minimum of 3
 
way too much for the light stalk..how many relays?
so u have in total 530w of lights inc headlights on the light stalk?

where's it say he's running them all through the stalk switch ? - he could have 1000s of watts switched via the stalk using the right relays
 
no he dint - he said "i wired them all up correctly (to the high beam)with all the relays and what not" - it dont say where the power is coming from - the headlights could be switching the relays, could it not?
 
the wipacs are 100w and the ring are 55w i think the relays are 30 amps and the inline fuse is 30amps :)

it has to be one of the relays, might be a good plan to fit some rated a lot higher than 30A

you may well have accidentally routed the full load through contacts only rated as specified and they've melted
 