Recent content by gregyzfr1
This site contains affiliate links for which LandyZone may be compensated if you make a purchase.
-
im in brandon l322 and p38 and an empty bank account
-
the fat orange wire connects to the thin black/purple wire there is a green wire & a black wire i know there is nothing wrong with the motor as it runs with diagnostics or by bridging terminals at relay 20
-
i have removed relay under seat & this throws up a fault so guessing its ok as for orange wire i was under the impression that this goes to thermal cut out & green wire runs to compressor i could be wrong as i say electrics are a mystery to me
-
checked fuse 29 looked good but replaced it, no change also orange wire to compressor goes live with engine running, should it?
-
long day spent working on rangey & achieved nothing electrics are a dark art to me but i definately have no power to pressure switch or at pin 13 on ecu the air is low now & switch has changed state where do i find the power supply? as i have no idea rave is no help either
-
lol ok no worries i dont have pressure gauges etc think i might put it back to springs need to many tools & money to fix this thanks all for your help
-
hi there thanks for the reply i ran the compressor manually for 10 mins till it reached full height once unplugged the valve block did all its clicking putting car to ride height
-
hi guys just about recovered from flu so back to repairing the rangy lol i`ve just test the pressure switch for continuity there is no change of state from empty of air to full pressure
this is the green switch fitted into the valve block i believe i had just replaced this with a brand new one...
-
hi thanks for the replies dont feel quite so alone now lol i tested the thermo switch by shaving back a small section of the orange wire just as in the link & ground it to earth it didnt run either but to be on the safe side i fitted a brand new one i also fitted a brand new pressure switch (the...
-
thanks all for your help looks like a trip to a specialist if that doesnt cure it then it back to crappy springs hey ho
-
i have a choice of 2 lol & tried both still the same
-
thanks but i tried that yesterday too completley drained system still no compressor i would just live with this but i tow a 3 ton compressor & after 10 miles she throws a fault & sits on the bump stops
-
ive swapped relay 20 for a known good one if i remove relay bridge terminals to run pump suspension will go to max height when i replace relay it drops to correct level
-
the dash switch is connected & lit i have tried another one it all seems to work as it should just no compressor i originaly bought my rangey on springs & recently bought another on air for spares so i changed everything over the only things missing on mine were the air bags & pump but over the...
-
the pump will only run if i use rsw software or bridge relay terminals there is good idle on software too