Cornishdefender
Active Member
- Posts
- 63
- Location
- West Cornwall
We've just had some stuff done on our '96 300TDI Defender - very long story but basically the most recent issue that has reared its head is the engine runs on after the ignition is turned off. If switched on from cold, then turned off immediately, no run on. If we go for a journey, say 20', then the run on is about 5-10 secs. Interestingly the run on happens even if the spade connector to the fuel injector pump is disconnected....!
We have just had the solenoid replaced - when the refurbed fuel injector pump was installed we got Landy home to then discover that there was a fuel leak from the top of solenoid - did wonder why the fuel gauge was going down so fast! So mechanic who installed the refurbed injector pump got a new solenoid from the refurbers and installed it on Wednesday. We discovered the run on issue on Thursday.
Given it happens even if the spade connector is disconnected presumably this points to the solenoid being the problem - is that right or are we missing something?
Thanks
We have just had the solenoid replaced - when the refurbed fuel injector pump was installed we got Landy home to then discover that there was a fuel leak from the top of solenoid - did wonder why the fuel gauge was going down so fast! So mechanic who installed the refurbed injector pump got a new solenoid from the refurbers and installed it on Wednesday. We discovered the run on issue on Thursday.
Given it happens even if the spade connector is disconnected presumably this points to the solenoid being the problem - is that right or are we missing something?
Thanks