300 Tdi Rebuild

Discussion in '300 TDi' started by Al2O3, Mar 11, 2017.

< Previous Thread | Next Thread >
  1. windy81

    windy81 Well-Known Member

    Joined:
    Jul 28, 2014
    Posts:
    393
    Likes Received:
    177
    blocked DPFs are more prevalent but amount to the same problem of exhaust back pressure.
    Have a read https://www.melett.com/technical/why-turbos-fail/can-dpf-cause-turbo-failure/

    "
    • Oil leaks into the compressor housing can be seen as a consequence of exhaust gas forcing its way into the CHRA from the turbine side and forcing oil through the oil seal on the compressor side.
    "
     
  2. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    That's very interesting, thank you. I don't know how they differ inside to a CAT, but that certainly sounds like something I need to investigate. The amount of soot and carbon around the piston crowns when I stripped the engine was shocking, so I could well imagine that whatever is inside the CAT could be choked. Cheers, mate :)
     
  3. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    @windy81 I'm going to try my local motor factors tomorrow to see what they can get me for Tuesday. Failing that, I'll order a full system from Paddocks or Craddocks on Tuesday. Many thanks. :)
     
  4. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    @windy81 local motor factors getting replacement front pipe and CAT in for me Tuesday morning (fingers crossed emoji)
     
  5. windy81

    windy81 Well-Known Member

    Joined:
    Jul 28, 2014
    Posts:
    393
    Likes Received:
    177
    blimey. Wouldn't it be best to check if it is blocked first. Fair play to you though. Might be an old rag down there
     
  6. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    No idea how I could check if it's blocked. The guy on the phone at the motor factors turned out to be a Landy enthusiast too, so we had a good chat. He said his sisters Saab 93 had a leaking turbo so they swapped it. New one still leaked and it turned out to be a blocked DPF.
     
  7. windy81

    windy81 Well-Known Member

    Joined:
    Jul 28, 2014
    Posts:
    393
    Likes Received:
    177
    definitely a possibility then. I'd de-cat it you know.
     
    Al2O3 likes this.
  8. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    It's an MOT failure now if you remove the CAT.
     
  9. v8250

    v8250 Well-Known Member

    Joined:
    Jun 23, 2019
    Posts:
    2,069
    Likes Received:
    2,230
    Location:
    Berkshire
    @Al2O3 , just seen your post here - could you not temporarily replace the CAT with a straight/flexile pipe to rule out CAT blockage?
     
  10. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    Hi Mate. Yes, but a straight pipe is about £80 and the pipe with the CAT in is £120, so I didn't think it was worth it. If it did cure the problem I would have to buy another CAT pipe before the next MOT anyway.
    When I took the head off in October 2019 the soot/carbon build up on top of the pistons was terrible.
    IMG_1524.JPG
    So, I should imagine the inside of the exhaust and particularly the CAT will be pretty bad too.
    I'm hoping that the problem started with the badly fitting return pipes. The problem is the Landy has run almost daily since the rebuild and has done over 30K miles, burning oil all the while. Now I've got the genuine return pipe on I'm hoping the cause of the problem has changed to the CAT being choked and the back pressure pushing exhaust gas and oil through the seals.
    It certainly sounds feasible that this is the problem now. I've got my fingers crossed big style.
     
    Last edited: Apr 2, 2021
    Disco1BFG and v8250 like this.
  11. Cavey_P38

    Cavey_P38 Well-Known Member Full Member

    Joined:
    Oct 8, 2009
    Posts:
    1,199
    Likes Received:
    450
    Location:
    The Flat lands of Cambridgeshire
    Good luck mate,
     
    Al2O3 likes this.
  12. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    Should have posted an update earlier tonight!
    Drove to motor factors just after lunch as they said the downpipe/CAT would be in their morning delivery. It wasn't :( They said it was being couriered in this afternoon and they would give me a call when it came in. So, I drove home (11 miles) and took the current downpipe off. I did get the call and I picked it up just after 5pm (they close at 5:30) I did have time to put it on, however, I've got a very wary grey squirrel that is eluding me. From my trail camera it's been turning up at the feeder at day break and sunset, so I went to the wood to wait for it tonight. It did turn up, but just foraged in the background, about four trees back from the feeder, and never came in range. :rolleyes: So, I'm up at 4:45 to be in place for it coming for it's breakfast at 5:45. Hopefully, it turns up on queue and I'll be back for a very early start putting the new pipe on. I'm the most nervous/excited I've been with anything I've ever done with the Landy :eek:
     
    v8250 likes this.
  13. windy81

    windy81 Well-Known Member

    Joined:
    Jul 28, 2014
    Posts:
    393
    Likes Received:
    177
    try and see if the current cat is blocked. It'll be interesting to see if this is the cause if not i'll feel bad about saying it as you've spent quite a bit
     
  14. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    Got the new down pipe and CAT on. Set up the turbo outlet test.
    Before picture
    20210407_113105.jpg
    Nice and clean.
    After the test drive
    20210407_115203.jpg
    Usual oil spray pattern from turbo outlet.
    Devastated :(
    If the issue is a bad oil return pipe causing a build up of oil pressure the seals work again once the fault is sorted. I presume the seals will work again if the problem was exhaust back pressure that's been sorted?

    Anyway, I might as well take the new downpipe/CAT off to save it getting choked with soot. Haven't got the go in me to do it just yet.
    Sat for three hours in the wood from 5:30 and didn't get the grey squirrel either. Bit of a sh1t day so far :rolleyes:
     
  15. windy81

    windy81 Well-Known Member

    Joined:
    Jul 28, 2014
    Posts:
    393
    Likes Received:
    177
    Gutted. Out of ideas now as to what this could be. You've literally tried everything.
    For sure oil is getting through the turbo and into the intake as to why that is nobody knows as the turbo is new, oil pressure is fine, correct oil, correct oil temperature, good oil return.

    If it's any comfort my newly rebuilt 200tdi is doing the same on a brand spanking new turbo from Turbo Technics and like yourself everything is brand new around it.

    Boggled
     
  16. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    Ahh no. That's bad news. Bloody hell :mad:
     
  17. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    Was your old turbo passing oil?
     
  18. windy81

    windy81 Well-Known Member

    Joined:
    Jul 28, 2014
    Posts:
    393
    Likes Received:
    177
    i'm wondering if its the oil itself as i use fully synthetic, legend has it it makes old cars leak but i doubt it
     
  19. windy81

    windy81 Well-Known Member

    Joined:
    Jul 28, 2014
    Posts:
    393
    Likes Received:
    177
    ye it was, the new one is a VGT whichis nice to drive i have to say. It drives nice just smells oily
     
  20. Al2O3

    Al2O3 Well-Known Member Full Member

    Joined:
    Apr 21, 2014
    Posts:
    9,874
    Likes Received:
    3,771
    Location:
    North of the Wall
    I don't think fully synthetic is the issue. I've tried different oils in mine anyway.
    How much oil are you getting through, have you tried to quantify it?
     