Hi chaps / chapesses,

We're talking about a '95 DT. HEVAC unit to be precise.

SYMPTOMS: every so often the blowers start pumping in red hot air and continue to do so. At the moment that means driving "windows doawn".

FAULTS: book symbol comes up. I've noticed it tends to do it after going over a bump so I think we're looking at a loose or bad connection somewhere, possibly a short from a rubbing cable. Unfortunately it keeps curing itself. So, half the time I go running in to get the Nanocom and by the time I've gone in and back out it has fixed itself. Fortunately, the other half of the time I get a fault code. After clearing (cycling ignition) and seeing them again, the 2 codes I'm seeing (never together) are:

(3) The Right Hand blend motor short (Fault type = current)

and (the more common one recently)

(32) Compressor clutch control circu (fault type = current).

Does this ring a bell with someone and it is a common problem? Or what would link the 2?

Just cleared the faults and then tried forcing every combination the Nanocom could throw at it. Everything working perfectly again (no need to calibrate as it was pretty much spot on) and damn book symbol and faults are mysteriously absent again. Guess I'll have to wait for it to recur unless anyone on here has some inspiration for me?

Cheers,

J
 
Hi chaps / chapesses,

We're talking about a '95 DT. HEVAC unit to be precise.

SYMPTOMS: every so often the blowers start pumping in red hot air and continue to do so. At the moment that means driving "windows doawn".

FAULTS: book symbol comes up. I've noticed it tends to do it after going over a bump so I think we're looking at a loose or bad connection somewhere, possibly a short from a rubbing cable. Unfortunately it keeps curing itself. So, half the time I go running in to get the Nanocom and by the time I've gone in and back out it has fixed itself. Fortunately, the other half of the time I get a fault code. After clearing (cycling ignition) and seeing them again, the 2 codes I'm seeing (never together) are:

(3) The Right Hand blend motor short (Fault type = current)

and (the more common one recently)

(32) Compressor clutch control circu (fault type = current).

Does this ring a bell with someone and it is a common problem? Or what would link the 2?

Just cleared the faults and then tried forcing every combination the Nanocom could throw at it. Everything working perfectly again (no need to calibrate as it was pretty much spot on) and damn book symbol and faults are mysteriously absent again. Guess I'll have to wait for it to recur unless anyone on here has some inspiration for me?

Cheers,

J

Sounds like the connector is falling off the back of the HEVAC since both faults relate to the HEVAC itself, the compressor clutch is operated direct by the HEVAC on a 95.
 
Could it be a faulty, or loose connection to the coolant sensor that's just near where the o rings are?

IIRC it just clips to the hot water pipes, it it's fallen off or the connection is loose the HEVAC might thing the coolant is much cooler than it is and so is adjusting the blend flap to try and warm things up a bit...?
 
Either of those doesn't sound too bad. When I've a spare moment I'll take the unit out and give it the once over, preferably before the cold weather comes. I can guarantee it'll fail completely then and revert to full air-con on on freeze!

Cheers,

J
 
If we do get a cold snap, you could always plug in your Nanocom, and force the blend motors to say 50% warmth, and then at least you'll not freeze whilst you look for the real culprit!
 
Had similar fault, the sensor had fallen off the pipes at the back, it was also faulty when I refitted it.

Be careful when you snap it on, the vibration can upset the great eco system that is the o rings!
 
The answer turned out to be somewhat surprising (to me). The thermostatic expansion valve (TXV) was jamming. Presumably this was causing the system to vent. This in turn lost all the gas causing the 32 fault.

Replaced the TXV and regassed. All working perfectly again. In fact, nearly froze testing it on a run to Didcot yesterday!
 