Hi guys and gals
Had a problem with my blend motors not blending but the heater control worked fine, I've had all three motors replaced blending fine now but it's not altering the temperature now it just blowing cold, could it be because the error message is still showing, do I need to get it cleared
 
Hi guys and gals
Had a problem with my blend motors not blending but the heater control worked fine, I've had all three motors replaced blending fine now but it's not altering the temperature now it just blowing cold, could it be because the error message is still showing, do I need to get it cleared
Needs diagnostics, fault normally clears when the fault is removed. Is it cold both sides?
 
Update datatek, passenger side getting warm drivers not, but it doesn't seem to be moving the air about ie from feet to vents seems to be stuck on windscreen
 
Ok cheers

Left and right blend motors have little to do (flaps very rarely, if ever, stick). So it's usually down to the motor. Distribution motor has an hell of a lot to do so it's usually down to stiff rear flaps or quadrant. Distribution flaps fore and aft and quadrant MUST be full and free in all aspects before motor is fitted or it will just stall. If quadrant is removed it MUST be refitted correctly to marks on fore and aft flap gears.
 