It's been naff here as well. Hoping to go away Friday long weekend bashing the bus around.Cheers mark will try that when the weather gives up a little
I meant just to check the clutch bobine, the system is checked with the correct gear as you knowI thought that don't jump to quickly for lack of gas. jump the AC clutch as @Mark Piercy.
When I did mine it worked and blew cold, so plenty gastrianary switch (or whatever its called) it can be tested to narrow down I did.
Got a new 1 and then had it degassed they replaced the switch regassed and hey presto cool as.
Have since read it is possible to change the said switch without degas but dont hold me to that.
J
I meant just to check the clutch bobine, the system is checked with the correct gear as you know
Boing!! ... Just ré read that.... Same page... Note to self.... Learn to read slowly... Ffs![]()
Any ideas where to start on my next hevac problem nanocom fault code (32) compressor clutch control circuit open or short to ground these p38s are a never ending battle just replaced the heater matrix and all new blend motors any advice as always much appreciated
It also occurs to me the clutch may not pull in if the gas pressure is too low. However, that can only mean 2 options: 1) the gas has leaked out somewhere, most like the condenser or 2) the TXV is acting up causing it to vent to atmosphere.
From memory mine was a green/ white wire which is powered from the tri pressure switch after a grant is received from the hevac. 97MY diesel.Cheers will try the hot wire with it running and check the gas in the system again for any leaks