To cut a long story short I replaced all 3 blend motors last month with new Valeo ones, as I had the book symbol and my Faultmate showed re-occurring issues with all 3.
Unfortunately as I didn't have my Faultmate with me when I replaced them so couldn't use the calibrate function.
After a month and about 250 miles the book symbol is back, I checked last night and it was reporting right hand blend motor stalled position. I cleared the fault ran a calibration I checked using the output and I could drive all 3 motors across the full range of their movement.
This morning on the way to work the book symbol returned and checking tonight I got right hand blend motor potentiometer circuit has failed, and checking the readings it is showing 122%.
I tried clearing the fault but it comes straight back, I then tried manual using the outputs to drive the blend motor but it just stayed T 122%, and also caused the ecu to generate another stalled fault as well.
Any suggestions how I might kick it back into life other than a new blend motor ?
Thanks,
Jamie.
Unfortunately as I didn't have my Faultmate with me when I replaced them so couldn't use the calibrate function.
After a month and about 250 miles the book symbol is back, I checked last night and it was reporting right hand blend motor stalled position. I cleared the fault ran a calibration I checked using the output and I could drive all 3 motors across the full range of their movement.
This morning on the way to work the book symbol returned and checking tonight I got right hand blend motor potentiometer circuit has failed, and checking the readings it is showing 122%.
I tried clearing the fault but it comes straight back, I then tried manual using the outputs to drive the blend motor but it just stayed T 122%, and also caused the ecu to generate another stalled fault as well.
Any suggestions how I might kick it back into life other than a new blend motor ?
Thanks,
Jamie.