It seems that you need to change the modulator, in that file with the fault codes(provided it's the one from autodata) is explained how to check resistance of the solenoid valves with multimeter so if you dont get around 7 Ohm between pins 21-27(fig 19) the solenoid within the modulator is gone or it's a wiring issue between the plug and modulator